abstract

  • Percutaneous renal artery stent placement has been demonstrated to improve blood pressure control and stabilize renal function in patients with atherosclerotic renal artery disease. However, this procedure is not without risk of significant morbidity, and its effectiveness, as compared to alternative treatments, has not been adequately established. The authors report a case of acute type B aortic dissection complicating renal artery stent placement. The authors postulate that an intimal disruption occurred during initial balloon angioplasty, and that repeated application of radial, shear, and torque forces during stent placement may have extended the injury. The diagnosis of acute aortic dissection should be considered in patients with suggestive symptoms immediately after stent placement.

publication date

  • April 1, 2001

Research

keywords

  • Angioplasty, Balloon
  • Aorta, Abdominal
  • Renal Artery Obstruction
  • Stents

Identity

Scopus Document Identifier

  • 0035065889

Digital Object Identifier (DOI)

  • 10.1016/s1051-0443(07)61893-4

PubMed ID

  • 11287541

Additional Document Info

volume

  • 12

issue

  • 4