Dosimetric analysis of a simplified intensity modulation technique for prone breast radiotherapy.
Academic Article
Overview
abstract
PURPOSE: Prone-position breast radiotherapy (RT) has been described as an alternative technique to improve dose homogeneity for women with large, pendulous breasts. We report the feasibility and dosimetric analysis of a simplified intensity-modulated RT (IMRT) technique, previously reported for women in the supine treatment position, to plan prone-position RT to the intact breast. METHODS AND MATERIALS: Twenty patients with clinical Stage TisN0-T1bN1 breast cancer undergoing breast-conserving therapy underwent whole breast RT using a prone position technique. The treatment plans were developed using both conventional tangents and a simplified intensity-modulated tangential beam technique based on optimization of the intensity distributions across the breast. The plans were compared with regard to the dose-volume parameters. RESULTS: Dose heterogeneity within the breast planning target volume was significantly greater for the conventional tangent plans. Of 20 patients, 16 (80%) received maximal doses of > or =110% using the conventional tangents vs. only 1 (5%) using the IMRT plan. The isodose level encompassing 5% of the planning target volume was reduced from an average of 110% with conventional tangents to 105% with IMRT. The maximal dose within the planning target volume was reduced from an average of 114% with conventional tangents to 107% with IMRT. The greatest improvement was seen in the patients with the most pendulous breasts. CONCLUSION: An IMRT planning approach is feasible for prone-position breast RT and improves dose homogeneity, particularly in women with larger, pendulous breasts. Additional follow-up is necessary to determine whether the improvements in dose homogeneity impact acute toxicity and cosmetic outcome in this cohort of women who have historically suffered from poor cosmesis after breast-conserving therapy.