Complications of pediatric femur fractures treated with titanium elastic nails: a comparison of fracture types. Academic Article uri icon

Overview

abstract

  • The purpose of this study was to analyze complications seen in children with femur fractures stabilized with titanium elastic nails, comparing their use in stable and unstable fracture patterns. A retrospective review was performed on 39 consecutive children with femur fractures treated with titanium elastic nails. Patients with comminuted or long oblique fractures were classified as having "length-unstable" fractures. Patients were analyzed qualitatively for any predictive factors or treatment variables that increased the risk of complications. There were 24 patients with complications (62%). Eight patients (21%) underwent unplanned surgery prior to complete fracture union. Six of the eight requiring unplanned surgery were treated for "length-unstable" fractures. The complications that required unplanned surgery for either prominent nails or loss of reduction occurred more commonly in unstable non-transverse fracture patterns. The authors conclude that in patients with "length-unstable" femur fractures, consideration should be given to methods of treatment other than titanium flexible intramedullary nails.

publication date

  • January 1, 2005

Research

keywords

  • Femoral Fractures
  • Fracture Fixation, Intramedullary

Identity

Scopus Document Identifier

  • 24144489720

Digital Object Identifier (DOI)

  • 10.1097/01.bpo.0000164872.44195.4f

PubMed ID

  • 16199934

Additional Document Info

volume

  • 25