Comparative assessment of antimicrobial activities of antibiotic-treated penile prostheses. Academic Article uri icon

Overview

abstract

  • BACKGROUND: Although infections associated with penile implants are relatively infrequent, they result in serious medical consequences. Because treatment of these infections usually requires removal of the infected penile implant, prevention of infection is crucial. Since bacterial colonization of the implant is a prelude to clinical infection, antimicrobial modification of the devices may inhibit device colonization and subsequent infection. OBJECTIVE: We compared the spectrum and durability, both in vitro and in vivo, of two antibiotic-treated penile prostheses: InhibiZone implants pre-impregnated with minocycline and rifampin (M/R) and Titan implants dipped in vancomycin. DESIGN, SETTING, AND PARTICIPANTS: 1×1-cm cylinder segments of (1) control untreated, (2) M/R-impregnated, and (3) vancomycin-dipped implants were studied. Baseline zones of inhibition (ZI) were determined against clinical isolates, including methicillin-resistant Staphylococcus aureus (MRSA), methicillin-resistant S. epidermidis (MRSE), vancomycin-resistant Enterococcus (VRE), and Escherichia coli. In addition, ZI against methicillin-susceptible S. aureus were compared both in vitro after being washed in a flow chamber and after subcutaneous implantation in rabbits for 1, 2, 7, and 14 d. MEASUREMENTS: ZI were measured as the diameter of the clear zone around each test device minus the external diameter of the device. RESULTS AND LIMITATIONS: Implants pre-impregnated with M/R displayed a broader spectrum of antimicrobial activity than vancomycin-dipped implants against both gram-positive and -negative bacteria. The M/R-impregnated devices also yielded significantly larger zones of inhibition against S. aureus than vancomycin-dipped implants, both in vitro (p<0.003) and in vivo throughout the 14-d period of device implantation in rabbits (p≤0.03). CONCLUSIONS: Penile prostheses impregnated with M/R have a broader spectrum in vitro and a more durable antimicrobial activity in vitro and in an animal model than implants dipped in vancomycin. Therefore, along with being a more practical model for incorporating antimicrobials onto the device, the use of implants pre-impregnated with M/R may help reduce the incidence of penile implant infection.

publication date

  • December 30, 2008

Research

keywords

  • Minocycline
  • Penile Prosthesis
  • Prosthesis-Related Infections
  • Rifampin
  • Vancomycin

Identity

Scopus Document Identifier

  • 70350567190

Digital Object Identifier (DOI)

  • 10.1016/j.eururo.2008.12.020

PubMed ID

  • 19135292

Additional Document Info

volume

  • 56

issue

  • 6