abstract

  • PURPOSE: To assess the incremental value of diffusion-weighted (DW) magnetic resonance (MR) imaging over T2-weighted MR imaging at 3 T for prostate cancer detection and to investigate the use of the apparent diffusion coefficient (ADC) to characterize tumor aggressiveness, with whole-mount step-section pathologic analysis as the reference standard. MATERIALS AND METHODS: The Internal Review Board approved this HIPAA-compliant retrospective study and waived informed consent. Fifty-one patients with prostate cancer (median age, 58 years; range, 46-74 years) underwent T2-weighted MR imaging and DW MR imaging (b values: 0 and 700 sec/mm(2) [n = 20] or 0 and 1000 sec/mm(2) [n = 31]) followed by prostatectomy. The prostate was divided into 12 regions; two readers provided a score for each region according to their level of suspicion for the presence of cancer on a five-point scale, first using T2-weighted MR imaging alone and then using T2-weighted MR imaging and the ADC map in conjunction. Areas under the receiver operating characteristic curve (AUCs) were estimated to evaluate performance. Generalized estimating equations were used to test the ADC difference between benign and malignant prostate regions and the association between ADCs and tumor Gleason scores. RESULTS: For tumor detection, the AUCs for readers 1 and 2 were 0.79 and 0.76, respectively, for T2-weighted MR imaging and 0.79 and 0.78, respectively, for T2-weighted MR imaging plus the ADC map. Mean ADCs for both cancerous and healthy prostatic regions were lower when DW MR imaging was performed with a b value of 1000 sec/mm(2) rather than 700 sec/mm(2). Regardless of the b value used, there was a significant difference in the mean ADC between malignant and benign prostate regions. A lower mean ADC was significantly associated with a higher tumor Gleason score (mean ADCs of [1.21, 1.10, 0.87, and 0.69] × 10(-3) mm(2)/sec were associated with Gleason score of 3 + 3, 3 + 4, 4 + 3, and 8 or higher, respectively; P = .017). CONCLUSION: Combined DW and T2-weighted MR imaging had similar performance to T2-weighted MR imaging alone for tumor detection; however, DW MR imaging provided additional quantitative information that significantly correlated with prostate cancer aggressiveness.

publication date

  • March 24, 2011

Research

keywords

  • Diffusion Magnetic Resonance Imaging
  • Prostatic Neoplasms

Identity

PubMed Central ID

  • PMC3099046

Scopus Document Identifier

  • 79956325077

Digital Object Identifier (DOI)

  • 10.1148/radiol.11102066

PubMed ID

  • 21436085

Additional Document Info

volume

  • 259

issue

  • 3