(124)I-huA33 antibody PET of colorectal cancer. Academic Article uri icon

Overview

abstract

  • UNLABELLED: Humanized A33 (huA33) is a promising monoclonal antibody that recognizes A33 antigen, which is present in more than 95% of colorectal cancers and in normal bowel. In this study, we took advantage of quantitative PET to evaluate (124)I huA33 targeting, biodistribution, and safety in patients with colorectal cancer. We also determined the biodistribution of (124)I-huA33 when a large dose of human intravenous IgG (IVIG) was administered to manipulate the Fc receptor or when (124)I-huA33 was given via hepatic arterial infusion (HAI). METHODS: We studied 25 patients with primary or metastatic colorectal cancer; 19 patients had surgical exploration or resection. Patients received a median of 343 MBq (44.4-396 MBq) and 10 mg of (124)I-huA33. Nineteen patients received the antibody intravenously and 6 patients via HAI, and 5 patients also received IVIG. RESULTS: Ten of 12 primary tumors were visualized in 11 patients. The median concentration in primary colon tumors was 0.016% injected dose per gram, compared with 0.004% in normal colon. The PET-based median ratio of hepatic tumor uptake to normal-liver uptake was 3.9 (range, 1.8-22.2). Quantitation using PET, compared with well counting of serum and tissue, showed little difference. Prominent uptake in bowel hindered tumor identification in some patients. Pharmacokinetics showed that patients receiving IVIG had a significantly shorter serum half-time (41.6 ± 14.0 h) than those without (65.2 ± 9.8 h). There were no differences in clearance rates among the intravenous group, IVIG group, and HAI group, nor was there any difference in serum area under the curve, maximum serum concentration, or volume of distribution. Weak titers of human-antihuman antibodies were observed in 6 of 25 patients. No acute side effects or significant toxicities were associated with huA33. CONCLUSION: Good localization of (124)I-huA33 in colorectal cancer with no significant toxicity has been observed. PET-derived (124)I concentrations agreed well with those obtained by well counting of surgically resected tissue and blood, confirming the quantitative accuracy of (124)I-huA33 PET. The HAI route had no advantage over the intravenous route. No clinically significant changes in blood clearance were induced by IVIG.

publication date

  • July 15, 2011

Research

keywords

  • Colorectal Neoplasms
  • Iodine Radioisotopes
  • Membrane Glycoproteins
  • Positron-Emission Tomography

Identity

PubMed Central ID

  • PMC3394182

Scopus Document Identifier

  • 80051675838

Digital Object Identifier (DOI)

  • 10.2967/jnumed.110.086165

PubMed ID

  • 21764796

Additional Document Info

volume

  • 52

issue

  • 8