In vitro and in vivo evaluation of (11)C-SD5024, a novel PET radioligand for human brain imaging of cannabinoid CB1 receptors. Academic Article uri icon

Overview

abstract

  • We recently developed a novel cannabinoid subtype-1 (CB1) receptor radioligand (11)C-SD5024 for brain imaging. This study aimed to evaluate (11)C-SD5024 both in vitro and in vivo and compare it with the other CB1 receptor ligands previously used in humans, i.e., (11)C-MePPEP, (11)C-OMAR, (18)F-MK-9470, and (18)F-FMPEP-d2. In vitro experiments were performed to measure dissociation constant (Ki) in the human brain and to measure the lipophilicity of the five CB1 receptor ligands listed above. In vivo specific binding in monkeys was measured by comparing total distribution volume (VT) at baseline and after full receptor blockade. The kinetics of (11)C-SD5024 in humans were evaluated in seven healthy subjects with compartmental modeling. SD5024 showed Ki=0.47nM, which was at an intermediate level among the five CB1 receptor ligands. Lipophilicity (LogD7.4) was 3.79, which is appropriate for brain imaging. Monkey scans showed high proportion of specific binding: ~80% of VT. In humans, (11)C-SD5024 showed peak brain uptake of 1.5-3 standardized uptake value, which was slightly higher than that of (11)C-OMAR and (18)F-MK-9470. One-compartment model showed good fitting, consistent with the vast majority of brain uptake being specific binding found in the monkey. Regional VT values were consistent with known distribution of CB1 receptors. VT calculated from 80 and 120min of scan data was strongly correlated (R(2)=0.97), indicating that 80min provided adequate information for quantitation and that the influence of radiometabolites was low. Intersubject variability for VT of (11)C-SD5024 was 22%, which was low among the five radioligands and indicated precise measurement. In conclusion, (11)C-SD5024 has appropriate affinity and lipophilicity, high specific binding, moderate brain uptake, and provides good precision to measure the binding. The results suggest that (11)C-SD5024 is slightly better than or equivalent to (11)C-OMAR and that both are suitable for clinical studies, especially those that involve two scans in one day.

publication date

  • September 25, 2013

Research

keywords

  • Brain
  • Carbon Radioisotopes
  • Positron-Emission Tomography
  • Radiopharmaceuticals
  • Receptor, Cannabinoid, CB1

Identity

PubMed Central ID

  • PMC3849221

Scopus Document Identifier

  • 84885738234

Digital Object Identifier (DOI)

  • 10.1016/j.neuroimage.2013.09.043

PubMed ID

  • 24076222

Additional Document Info

volume

  • 84