2D mammography, digital breast tomosynthesis, and ultrasound: which should be used for the different breast densities in breast cancer screening?
Academic Article
Overview
abstract
PURPOSE: To determine which modalities [2D mammography (2D), digital breast tomosynthesis (DBT), whole breast sonography (WBS)] are optimal for screening depending on breast density. METHODS: Institutional retrospective cohort study of 2013 screening mammograms (16,789), sorted by modalities and density. RESULTS: Cancer detection is increased by adding WBS to 2D (P=.02) for the overall study population. Recall rate was lowest with 2D+DBT (10.2%, P<.001) and highest with 2D+DBT+WBS (23.6%, P<.001) for the overall study population as well. CONCLUSION: Women with dense and nondense breasts benefit from reduced recall rate with the addition of DBT; however, this benefit is negated with the addition of WBS.