North American Multicenter Volumetric CT Study for Clinical Staging of Malignant Pleural Mesothelioma: Feasibility and Logistics of Setting Up a Quantitative Imaging Study. Academic Article uri icon

Overview

abstract

  • BACKGROUND: Clinical tumor (T), node, and metastasis staging is based on a qualitative assessment of features defining T descriptors and has been found to be suboptimal for predicting the prognosis of patients with malignant pleural mesothelioma (MPM). Previous work suggests that volumetric computed tomography (VolCT) is prognostic and, if found practical and reproducible, could improve clinical MPM classification. METHODS: Six North American institutions electronically submitted clinical, pathologic, and imaging data on patients with stages I to IV MPM to an established multicenter database and biostatistical center. Two reference radiologists blinded to clinical data independently reviewed the scans; calculated clinical T, node, and metastasis stage by standard criteria; performed semiautomated tumor volume calculations using commercially available software; and submitted the findings to the biostatistical center. Study end points included the feasibility of a multi-institutional VolCT network, concordance of independent VolCT assessments, and association of VolCT with pathological T classification. RESULTS: Of 164 submitted cases, 129 were evaluated by both reference radiologists. Discordant clinical staging of most cases confirmed the inadequacy of current criteria. The overall correlation between VolCT estimates was good (Spearman correlation 0.822), but some were significantly discordant. Root cause analysis of the most discordant estimates identified four common sources of variability. Despite these limitations, median tumor volume estimates were similar within subgroups of cases representing each pathological T descriptor and increased monotonically for each reference radiologist with increasing pathological T status. CONCLUSIONS: The good correlation between VolCT estimates obtained for most cases reviewed by two independent radiologists and qualitative association of VolCT with pathological T status combine to encourage further study. The identified sources of user error will inform design of a follow-up prospective trial to more formally assess interobserver variability of VolCT and its potential contribution to clinical MPM staging.

publication date

  • May 12, 2016

Research

keywords

  • Cone-Beam Computed Tomography
  • Lung Neoplasms
  • Mesothelioma
  • Pleural Neoplasms

Identity

PubMed Central ID

  • PMC5075991

Scopus Document Identifier

  • 84982126157

Digital Object Identifier (DOI)

  • 10.1016/j.jtho.2016.04.027

PubMed ID

  • 27180318

Additional Document Info

volume

  • 11

issue

  • 8