  • OBJECTIVES: This study sought to evaluate this transcatheter aortic valve (TAV) bioprosthesis in patients who are poorly suitable for surgical aortic valve (AV) replacement. BACKGROUND: A novel self-expandable TAV bioprosthesis was designed to provide a low-profile delivery system, conformable annular sealing, and the ability to resheath and reposition during deployment. METHODS: The Evolut R U.S. study included 241 patients with severe aortic stenosis who were deemed to be at least high risk for surgery treated at 23 clinical sites in the United States. Clinical outcomes at 30 days were evaluated using Valve Academic Research Consortium-2 criteria. An independent echocardiography laboratory was used to evaluate hemodynamic outcomes. RESULTS: Patients were elderly (83.3 ± 7.2 years of age) and had high surgical risk (Society of Thoracic Surgeons predicted risk of mortality of 7.4 ± 3.4%). The majority of patients (89.5%) were treated by iliofemoral access. Resheathing or recapturing was performed in 22.6% of patients; more than 1 valve was required in 3 patients (1.3%). The 30-day outcomes included all-cause mortality (2.5%), disabling stroke (3.3%), major vascular complications (7.5%), life-threatening or disabling bleeding (7.1%), and new permanent pacemaker (16.4%). AV hemodynamics were markedly improved at 30 days: the mean AV gradient was reduced from 48.2 ± 13.0 mm Hg to 7.8 ± 3.1 mm Hg (p < 0.001) and AV area increased from 0.6 ± 0.2 cm2 to 1.9 ± 0.5 cm2 (p < 0.001). Moderate residual paravalvular leak was identified in 5.3% of patients. CONCLUSIONS: We conclude that this novel self-expanding TAV bioprosthesis is safe and effective for the treatment of patients with severe aortic stenosis who are suboptimal for surgery. (Medtronic CoreValve Evolut R U.S. Clinical Study; NCT02207569).

authors

  • Popma, Jeffrey J
  • Reardon, Michael
  • Khabbaz, Kamal
  • Harrison, J Kevin
  • Hughes, G Chad
  • Kodali, Susheel
  • George, Isaac
  • Deeb, G Michael
  • Chetcuti, Stan
  • Kipperman, Robert
  • Brown, John
  • Qiao, Hongyan
  • Slater, James
  • Williams, Mathew R

publication date

  • February 13, 2017

Research

keywords

  • Aortic Valve
  • Aortic Valve Stenosis
  • Bioprosthesis
  • Heart Valve Prosthesis
  • Transcatheter Aortic Valve Replacement

Identity

Scopus Document Identifier

  • 85011866901

Digital Object Identifier (DOI)

  • 10.1016/j.jcin.2016.08.050

PubMed ID

  • 28183466

Additional Document Info

volume

  • 10

issue

  • 3