Use of a Small-Bore Needle Arthroscope to Diagnose Intra-Articular Knee Pathology: Comparison With Magnetic Resonance Imaging. Academic Article uri icon

Overview

abstract

  • The use of arthroscopy for purely diagnostic purposes has been largely supplanted by noninvasive technologies, such as magnetic resonance imaging (MRI). The mi-eye+TM (Trice Medical) technology is a small-bore needle unit for in-office arthroscopy. We conducted a pilot study comparing the mi-eye⁺™ unit with MRI, using surgical arthroscopy as a gold-standard reference. We hypothesized that the mi-eye⁺™ needle arthroscope, which can be used in an office setting, would be equivalent to MRI for the diagnosis of intra-articular pathology of the knee. This prospective, multicenter, observational study was approved by the Institutional Review Board. There were 106 patients (53 males, 53 females) in the study. MRIs were interpreted by musculoskeletally trained radiologists. The study was conducted in the operating room using the mi-eye⁺™ device. The mi-eye⁺™ device findings were compared with the MRI findings within individual pathologies, and a "per-patient" analysis was performed to compare the arthroscopic findings with those of the mi-eye⁺™ and the MRI. Additionally, we identified all mi-eye⁺™ findings and MRI findings that exactly matched the surgical arthroscopy findings. The mi-eye⁺™ demonstrated complete accuracy of all pathologies for 97 (91.5%) of the 106 patients included in the study, whereas MRI demonstrated complete accuracy for 65 patients (61.3%) (P < .0001). All discrepancies between mi-eye⁺TM and arthroscopy were false-negative mi-eye⁺™ results, as the mi-eye⁺TM did not reveal some aspect of the knee's pathology for 9 patients. The mi-eye⁺™ was more sensitive than MRI in identifying meniscal tears (92.6% vs 77.8%; P = .0035) and more specific in diagnosing these tears (100% vs 41.7%; P < .0001). The mi-eye⁺™ device proved to be more sensitive and specific than MRI for intra-articular findings at time of knee arthroscopy. Certainly there are contraindications to using the mi-eye⁺™, and our results do not obviate the need for MRI, but our study did demonstrate that the mi-eye⁺™ needle arthroscope can safely provide excellent visualization of intra-articular knee pathology.

publication date

  • February 1, 2018

Research

keywords

  • Arthroscopy
  • Joint Diseases
  • Knee Injuries
  • Knee Joint

Identity

Scopus Document Identifier

  • 85052837755

Digital Object Identifier (DOI)

  • 10.12788/ajo.2018.0007

PubMed ID

  • 29494711

Additional Document Info

volume

  • 47

issue

  • 2