Single- Versus Double-Row Repair of Hip Abductor Tears: A Biomechanical Matched Cadaver Study. Academic Article uri icon

Overview

abstract

  • PURPOSE: The purposes of this study were (1) to evaluate the percentage of gluteus medius and minimus tendon footprint restoration that can be achieved with fixation using single-row repair versus double-row repair and (2) to evaluate the yield load of a repair of the gluteus medius and minimus tendon using single-row versus double-row repair techniques. METHODS: Twelve human fresh-frozen cadaveric hip specimens (6 matched pairs, 4 female, mean age 47.5 ± 14.5 years) were tested. Specimens were excluded if they had any prior hip surgery or injury, if any abnormality of the tendon was noted on dissection, or if they had a body mass index <20 or >35 or a T-score <2.0 on dual-energy x-ray absorptiometry scanning. Matched pairs were randomized to receive either double-row repair with 2 standard suture anchors and 2 knotless anchor devices or a single-row repair with suture anchors only. The percentage of the footprint area covered after repair was determined using a computer-assisted digitization algorithm. With a mechanical testing system, each repaired specimen was tested for mechanical strength first with cyclic loading and then load to failure testing. RESULTS: Footprint coverage of the lateral facet was significantly greater for double-row repair (mean 76.6%) compared with single-row repair (mean 50.3%) (P = .03). There was no significant difference between single- and double-row repair for posterior-superior or anterior facet coverage. Mechanical testing showed a higher mean yield load for double-row anchor repair (197.6 ± 61.7 N vs 163.5 ± 35.4 N for single-row repair), but this did not reach statistical significance (P = .15). The predominant mode of failure was suture pullout through the musculotendinous unit (9/12 specimens: 5 double-row and 4 single-row). CONCLUSIONS: For hip abductor tears, double-row suture repair yields improved footprint coverage compared with single-row repair. Although it did not reach statistical significance, there was a higher mean yield load in the double-row group. CLINICAL RELEVANCE: Double-row suture fixation technique for hip abductor tears maximizes strength and footprint coverage of the repair.

publication date

  • February 4, 2019

Research

keywords

  • Tendon Injuries

Identity

Scopus Document Identifier

  • 85060917287

Digital Object Identifier (DOI)

  • 10.1016/j.arthro.2018.10.146

PubMed ID

  • 30733037

Additional Document Info

volume

  • 35

issue

  • 3