Outcomes of Expandable Interbody Devices in Lumbar Fusion: A Systematic Review and Meta-analysis. Review uri icon

Overview

abstract

  • STUDY DESIGN: This was a systematic review. OBJECTIVE: The objective of this study was to review radiographic, clinical, and surgical outcomes of expandable interbody device implantation following lumbar fusion. SUMMARY OF BACKGROUND DATA: Few studies have evaluated postsurgical outcomes of expandable implants following lumbar interbody fusion. METHODS: A systematic review was performed to identify studies investigating expandable intervertebral body devices in lumbar fusion. Radiographic parameters, fusion assessments, patient-reported outcomes (PROs), complications, and revision data were recorded. A comparison of expandable and static devices was performed using a meta-analysis. RESULTS: Eleven articles were included. Postoperative improvements for each radiographic parameters for expandable versus static device implantation ranged from: lumbar lordosis, +2.0 to +5.0 degrees (expandable) versus +1.0 to +4.4 degrees (static); segmental lordosis, +1.0 to +5.2 degrees (expandable) versus+1.1 to +2.3 degrees (static); disk height, +0.82 to +4.8 mm (expandable) versus +0.26 to +6.9 mm (static); foraminal height, +0.13 to +2.8 mm (expandable) versus and +0.05 to +3.0 mm (static). Fusion rates ranged from 72.1% at 6 months to 100% at terminal follow-up. Preoperative to final follow-up improvement for the various PROs assessed were: Oswestry Disability Index, -15.4 to -56.3 (expandable) versus -13.6 to -26.3 (static); Visual Analog Scale (VAS) Back, -3.2 to -6.0 (expandable) versus -3.1 to -4.1 (static); and VAS Leg, -2.9 to -7.1 (expandable) -3.0 versus -4.8 (static). Static cages had a reported complication rate ranging from 6.0% to 16.1% and a subsidence rate of 6.0%. Expandable cages had a reported complication rate that ranged from 0.0.% to 10.0% and a subsidence rate of 5.5%-10.0%. A meta-analysis demonstrated a statistically significant difference in the PRO Oswestry Disability Index, but not VAS Back, VAS Leg, or radiographic outcomes (disk height or foraminal height). CONCLUSION: There is no clear evidence for the use of expandable interbody devices over static devices.

publication date

  • July 1, 2020

Research

keywords

  • Internal Fixators
  • Lordosis
  • Lumbar Vertebrae
  • Lumbosacral Region
  • Spinal Fusion

Identity

Scopus Document Identifier

  • 85081618328

Digital Object Identifier (DOI)

  • 10.1097/BSD.0000000000000959

PubMed ID

  • 32101992

Additional Document Info

volume

  • 33

issue

  • 6