Late proptosis following orbital floor fracture repair. Academic Article uri icon

Overview

abstract

  • OBJECTIVE: Late proptosis is an unusual complication of orbital floor fracture repair. We report 12 cases and propose a classification scheme and differential diagnosis for this rare complication. DESIGN: Retrospective multi-institutional case review. SETTING: Two tertiary referral centers. RESULTS: We report 12 cases of late proptosis following orbital floor fracture repair. Causes of late proptosis include peri-implant inflammation, capsular hemorrhage, gelatin film cyst, implant infection, sino-orbital fistula, intraorbital sinus mucocele, and carotid-cavernous fistula. We describe the treatment of each case individually; in most cases, the implant was removed. All 12 patients had a satisfactory outcome after treatment. CONCLUSIONS: Proptosis presenting 2 months or more after orbital floor fracture is rare. We classify the origin of late proptosis into three groups: implant, sinus, and neurovascular. We describe the diagnosis and management of this unusual complication.

publication date

  • June 1, 1995

Research

keywords

  • Exophthalmos
  • Orbital Fractures

Identity

Scopus Document Identifier

  • 0029063549

Digital Object Identifier (DOI)

  • 10.1001/archotol.1995.01890060047009

PubMed ID

  • 7772317

Additional Document Info

volume

  • 121

issue

  • 6