Cervical carcinoma: determination of recurrent tumor extent versus radiation changes with MR imaging. Academic Article uri icon

Overview

abstract

  • PURPOSE: To evaluate the effectiveness of magnetic resonance (MR) imaging for assessment of the present and extent of tumor recurrence as determined with pathologic and surgical findings. MATERIALS AND METHODS: MR findings were retrospectively examined in 37 patients with a history of cervical carcinoma. Inter- and intraobserver variability was analyzed. Surgical or pathologic results were acquired in 34 of these patients; the remaining three patients were clinically followed up for at least 4 years. RESULTS: MR imaging allowed correct detection of recurrent tumor in 18 of 21 patients who had histologically documented recurrence. It helped correctly exclude recurrent disease in 15 of 16 patients. Sensitivity and specificity for detection of recurrence was 86% and 94%, respectively. Good intra- and interobserver agreement was demonstrated. CONCLUSION: MR imaging is a useful modality for differentiation of recurrent cervical carcinoma from radiation changes. Determination of the extent of recurrence with MR imaging may offer clinical assistance in the selection of optimal therapy.

publication date

  • January 1, 1995

Research

keywords

  • Carcinoma, Squamous Cell
  • Magnetic Resonance Imaging
  • Neoplasm Recurrence, Local
  • Uterine Cervical Neoplasms

Identity

Scopus Document Identifier

  • 0028959061

Digital Object Identifier (DOI)

  • 10.1148/radiology.194.1.7997540

PubMed ID

  • 7997540

Additional Document Info

volume

  • 194

issue

  • 1