Postoperative femoral fracture after intramedullary fixation with a Gamma nail: case report and review of the literature. Review uri icon

Overview

abstract

  • The Gamma nail, an intramedullary nail that is combined with a sliding hip screw, has recently been introduced as an alternative method of treatment for peritrochanteric fractures of the femur. We report a case of a postoperative femoral fracture that occurred in the area of the device after Gamma nailing of a stable intertrochanteric fracture. A review of the literature reveals that postoperative fracture is not an uncommon complication of Gamma nailing. This complication results in a difficult management problem. The possibility of a femoral fracture around the Gamma nail should be entertained before the use of the nail is considered. The availability of alternative fixation devices must be confirmed in the event that such a fracture is encountered.

publication date

  • July 1, 1994

Research

keywords

  • Femoral Fractures
  • Fracture Fixation, Intramedullary
  • Hip Fractures
  • Internal Fixators

Identity

Scopus Document Identifier

  • 0028141990

Digital Object Identifier (DOI)

  • 10.1097/00005373-199407000-00025

PubMed ID

  • 8028052

Additional Document Info

volume

  • 37

issue

  • 1