Preoperative biopsy of pararectal lymph nodes in rectal cancer using endoluminal ultrasonography. Academic Article uri icon

Overview

abstract

  • PURPOSE: Because definitive information regarding lymph node status in rectal cancer would be valuable preoperatively, we evaluated the safety, feasibility, and accuracy of performing endoluminal ultrasound-guided biopsies of pararectal lymph nodes in 26 rectal cancer patients. Biopsies were compared with the pararectal tissues removed at surgery. METHODS: Using a longitudinally oriented 7.0-MHz ultrasound probe and an 18-gauge spring-loaded core biopsy needle, patients underwent biopsies of lymph nodes detected ultrasonographically without complications. RESULTS: A biopsy of adenocarcinoma was obtained in 13 patients, lymphoid material in 5 patients, and irrelevant material in 8 patients. Accuracy rate (true positives divided by number of procedures) was 77 percent, with a sensitivity of 71 percent, a specificity of 89 percent, a positive predictive value of 92 percent, and a negative predictive value of 62 percent. When adenocarcinoma or lymphoid material was obtained, there was only one false positive and one false negative. CONCLUSION: Endoluminal ultrasonography-guided lymph node biopsy is simple and safe, and when adenocarcinoma or lymphoid material is obtained on biopsy, clinical decision making can be based on this information.

publication date

  • April 1, 1994

Research

keywords

  • Adenocarcinoma
  • Biopsy, Needle
  • Lymph Nodes
  • Rectal Neoplasms

Identity

Scopus Document Identifier

  • 0028325242

Digital Object Identifier (DOI)

  • 10.1007/BF02053598

PubMed ID

  • 8168415

Additional Document Info

volume

  • 37

issue

  • 4