  • We studied the renal arteries prospectively in 16 patients with renal insufficiency using a combination of two-dimensional and three-dimensional time of flight magnetic resonance angiography (MRA). Results were compared with conventional angiography. All renal arteries were identified by MRA. Accuracy for classifying renal arteries into patent, moderately (30-70%) stenotic, severely (> 70%) stenotic, or occluded was 91%. With regard to the presence or absence of severe occlusive disease (> 70% stenosis or occlusion) the sensitivity was 100%, with a specificity of 93%.

publication date

  • January 1, 1993

Research

keywords

  • Magnetic Resonance Imaging
  • Renal Artery
  • Renal Insufficiency

Identity

Scopus Document Identifier

  • 0027519659

Digital Object Identifier (DOI)

  • 10.1016/0730-725x(93)90211-u

PubMed ID

  • 8231678

Additional Document Info

volume

  • 11

issue

  • 7